Handly Scope MS-2000
Handly Scope MS-2000 is a Oscilloscope equivalent with powerfull waveform display, True RMS, autoranging DMM & Frequency Counter - 10MHz
Graphic Mode

Numeric mode
|
Digital Storage Oscilloscope
- DC to 2MHz, 1 Channel
- Vertical Sensitivity : 0.1 V/div ~ 100v/div
- Horizontal Sweep : 2µs/div ~ 2s/div
- Trigger : Auto, Normal
- Cursor : D V, D T
- Auto set up
- Save / Load
- Sampling rate : 10MS/s
- Probe Type : test Leads
- Auto Power off
Digital Multimeter
- 3 ¾ digit Display (3999 count), Auto Range
- True RMS
- DC/AC V, DC/AC A, W , Capacitance, Diode, Continuity, Logic
- Analog Bar Graph, Buzzer Sound
- REL, MAX/MIN, dBm
Frequency Counter
- 5Hz to 10MHz, 1 Channel
- High Resolution : 5 Digits
- Auto/Manual Range
|
Digital Storage Oscilloscope Handly Scope MS-2000
General Specification
Common Features
Display Type : Graphic LCD (EL Back light)
Dot number : 200 x 200 dots (W x H)
RS-232C Interface & print readout
Baud Rate : 9600 bps
Hold/Run Function
Save/Load for Waveform and Setup Date
(10 Channels)
Power Source & Physical Specification
AC Power Adaptor : 7.5V/2A
Rechargeable Battery : Ni-MH Battery Pack(1.2Vx4pcs)
Dimmension : 97 x 50 x 207mm (W x H x D)
Weight : approx 650g
Accessories
Standard : Unit, Holster, Test leads, AC Adaptor, Owner's Manual
Option : Ni-MH Battery Pack, RS-232C cable & 3.5" program disk, Carrying case
Technical Specification
|
Digital Storange Oscilloscope
|
|
Vertical
|
Input Channel
Sensitivity
Frequency Bandwidth
Rising Time
Input Coupling
Input Impedance
Input Damage
Probe Type
|
1 channel
0.1V/div. ~ 100V/div.
DC ~ 2MHz
Less Than 140ns
AC, DC
100MW ± 2% //less than 50pF
± 350V (DC+AC) peak max.
Test Leads ( only x 1)
|
|
Horizantal
|
Sweep Time
One Shot
Roll
Sweep Mode
H Position
|
0.2µ/div. - 0.1s/div
0.2s/div - 2s/div
Auto,Normal
0 - 50 div.(One Shot mode)
0 - 8 div. (Roll mode)
|
|
Trigger Mode
|
Coupling
Slope
Resolution
Sensivity
Position
|
DC only
Rising, Faling
128 Points (7bits)
0.8div (DC to 500KHz)
1.2div (500KHz to 2MHz)
0 - 8th
|
|
A/D Convert
|
Resolution
Sampling
Type
|
8Bits(256)
10MS/s
Flash Type
|
|
Display
|
Resolution
Graticle Line
|
20 Points/div
8 div ( Vertical )
8 div ( Horizontal )
|
|
Data Length
|
One Shot
Roll
|
1000 Points
160 Points
|
|
Cursor
|
Kind
Effect Value
|
D V, D T
3 Digits
|
|
Auto Setup
|
|
Digital Multimeter
|
|
General Features
|
3 ¾ digit (3999 Counts) with Analog Bargraph display
True RMS
Auto/Manual range selectable
REL, MAX/MIN, dBm
|
|
DC Voltage
|
Range
Accurancy
|
400mV - 600V
0.3% Full scale
|
|
AC Volatge
|
Range
Conversion
Accuracy
|
400mV - 600mV
True RMS
3% Full scale
|
|
DC Current
|
Range
Accurancy
|
400µA - 400mA
1.5% Full scale
|
|
AC Current
|
Range
Conversion
Accuracy
|
400µA - 400mA
True RMS
3% Full scale
|
|
Resistance
|
Range
Accurancy
|
400W - 40MW
2.5% Full scale
|
|
Diode
|
Open Termnial Voltage
Accuracy
Measuring Current
|
4V max.
0.3% Full scale
3mA
|
|
Continuity
|
Less than 100mV
|
|
Frequency Counter
|
Range
LCD Display
Mode
Input Source
Input Coupling
Input Impedance
|
5Hz - 10MHz
5 Digits
Auto / Manual selectable
DSO input
DC only
10MW ± 2% // less than 50pF
|
|
|
 |
|
 |
|